Deltatop DPO10E | Deltatop DPO10A | Deltatop DPO12E | Deltatop DPO12A | Deltatop DPO15E | Deltatop DPO15A | Deltatop DPP10 | Deltaset DPO50E | Deltaset DPO50A | Deltaset DPO51E | Deltaset DPO51A | Deltaset DPO52E | Deltaset DPO52A | Deltaset DPO53E | Deltaset DPO53A | Deltaset DPP50 | |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Measuring principle
|
Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P | Delta P |
Main features
|
Undivided orifice plate with corner taps, DIN19205(B) / ISO5167, orifice SS316Ti, for flanges DIN263x and 3-way manifold. DELTABAR-S ready mounted and adjusted. |
Undivided orifice plate with corner taps, DIN19205(B) / ISO5167, orifice SS316Ti,for flanges ANSI B16.5 and 3-way manifold. DELTABAR-S ready mounted and adjusted. |
Orifice flanges (DIN19214) orifice SS316Ti, with metal graphite sealing and 3-way manifold. DELTABAR-S ready mounted and adjusted. |
Orifice flanges ANSI B16.36 orifice SS316Ti, with metal graphite sealing and 3-way manifold. DELTABAR-S ready mounted and adjusted. |
Orifice SS316Ti in pipe, pipe with flanges DIN263x and 3-way manifold. DELTABAR-S ready mounted and adjusted. |
Orifice SS316Ti in pipe, pipe with flanges ANSI B16.5 and 3-way manifold. DELTABAR-S ready mounted and adjusted. |
Pitot tube, SS 316Ti, metal graphite sealing, incl. 3-way manifold, ready mounted and adjusted. | Undivided orifice plate with corner taps, DIN19205(B) / ISO5167, orifice SS316Ti, for flanges DIN263x. Separately ordered valves DPV50 resp. condensate chambers DPC50 premounted, DELTABAR-S optimized and adjusted. |
Undivided orifice plate with corner taps, DIN19205(B) / ISO5167, orifice SS316Ti,for flanges ANSI B16.5 Separately ordered valves DPV50 resp. condensate chambers DPC50 premounted, DELTABAR-S optimized and adjusted. |
Annular chamber orifice with corner taps, DIN19205(A) / ISO5167, orifice SS316Ti, for flanges DIN263x. Internal flat packing. Separately ordered valves DPV50 resp. condensate chambers DPC50 premounted, DELTABAR-S optimized and adjusted. |
Annular chamber orifice with corner taps, DIN19205(A) / ISO5167 orifice SS316Ti, for flanges ANSI B16.5 Internal flat packing. Separately ordered valves DPV50 resp. condensate chambers DPC50 premounted, DELTABAR-S optimized and adjusted. |
Orifice flanges DIN19214, orifice SS316Ti, with metal graphite sealing. Separately ordered valves DPV50 resp. condensate chambers DPC50 premounted, DELTABAR-S optimized and adjusted. |
Orifice flanges ANSI B16.36 orifice SS316Ti, with metal graphite sealing. Separately ordered valves DPV50 resp. condensate chambers DPC50 premounted, DELTABAR-S optimized and adjusted. |
Orifice plate acc. to DIN19206 Material SS316Ti for D-D/2 or flange tapping. Flanges/ plate installation by user. Separately ordered dP transmitter DELTABAR-S optimized and adjusted. | ANSI Orifice plate Material SS 316 Ti for D-D/2 or flange tapping. Flanges/ plate installation by user. Separately ordered dP transmitter DELTABAR-S optimized and adjusted. | Pitot tube, SS 316Ti. Separately ordered valves DPV50 resp. condensate chambers DPC50 premounted, DELTABAR-S optimized and adjusted. |
Diameter
|
DN 50 ... 1000 | 2" ... 24" | DN 50 ... 500 | 2" ... 24" | DN 10 ... 40 | 1/2" ... 1 1/2" | DN 25 ... 12000 | DN 50 ... 1000 | 2" ... 24" | DN 50 ... 1000 | 2" ... 24" | DN 50 ... 500 | 2" ... 24" | DN 50 ... 1000 | 2" ... 40" | DN 25 ... 10000 |
Measuring range
|
0.5...200?000 m3/h | 0,5...200'000 m3/h | 0.5...50?000 m3/h | 0,5...50'000 m3/h | 0.05...350 m3/h | 0,05...350 m3/h | 2...200?000 m3/h | 0.5...200?000 m3/h | 0,5...200'000 m3/h | 0.5...200?000 m3/h | 0,5...200'000 m3/h | 0.5...50?000 m3/h | 0,5...50'000 m3/h | 0.5...200?000 m3/h | 0,5...200'000 m3/h | 2...200?000 m3/h |
Process temperature
|
-200 °C ... +200 °C | -200 °C ... +200 °C | -200 °C ... +200 °C | -200 °C ... +200 °C | -200 °C ... +200 °C | -200 °C ... +200 °C | -200 °C ... +200 °C | -200 °C ... +1000 °C | -200 °C ... +1000 °C | -200 °C ... +1000 °C | -200 °C ... +1000 °C | -200 °C ... +1000 °C | -200 °C ... +1000 °C | -200 °C ... +1000 °C | -200 °C ... +1000 °C | -200 °C ... +200 °C |
Pressure range
|
Vacuum ... 160 bar abs | Vacuum ... 160 bar abs | Vacuum ... 100 bar abs | Vacuum ... 100 bar abs | Vacuum ... 100 bar abs | Vacuum ... 100 bar abs | Vacuum ... 160 bar abs | Vacuum ... 160 bar abs | Vacuum ... 160 bar abs | Vacuum ... 100 bar abs | Vacuum ... 100 bar abs | Vacuum ... 100 bar abs | Vacuum ... 100 bar abs | Vacuum ... 160 bar abs | Vacuum ... 160 bar abs | Vacuum ... 160 bar abs |
Accuracy
|
< 1 % | < 1 % | < 1 % | < 1 % | < 1 % | < 1 % | < 2 % | < 1 % | < 1 % | < 1 % | < 1 % | < 1 % | < 1 % | < 1 % | < 1 % | < 2 % |
Display/Operation
|
Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter | Transmitter |
Outputs
|
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Transmitter: 4 ... 20 mA |
Communication
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Ex-Approvals
|
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Protection electronic
|
IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
Features
|
Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) | Transmitter (Deltabar S) replaceable without interrupting the process (for modernising or maintenance) |
Advantages
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Components
|
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: |
Transmitter: Valve: Manifold: |
Transmitter: Valve: Manifold: |
Transmitter: Valve: Manifold: |
Transmitter: Valve: Manifold: |
Transmitter: Valve: Manifold: |
Transmitter: Valve: Manifold: |
Transmitter: Valve: Manifold: |
Transmitter: Valve: Manifold: |
Transmitter: Valve: Manifold: |