Prowirl 72F |
Prowirl 72W |
Prowirl 73F |
Prowirl 73W |
Prowirl 70H |
 |
 |
 |
 |
 |
Measuring principle
|
Vortex |
Vortex |
Vortex |
Vortex |
Vortex |
Main features
|
Reliable flow measurement of gas, steam and liquids |
Reliable flow measurement of gas, steam and liquids |
Reliable Flow Measurement of Gas, Steam and Liquids. Vortex flowmeter, temperature probe and flow computer in one device. |
Reliable Flow Measurement of Gas, Steam and Liquids. Vortex flowmeter, temperature probe and flow computer in one device. |
Reliable flow measurement of gas, steam and liquids |
Diameter
|
DN 15...300
1/2"...12"
|
DN 15...150
1/2"...6"
|
DN15...300
1/2"...12"
|
DN 15...150
1/2"...6"
|
DN 15...150
1/2"...6"
|
Measuring range
|
0.16...2'360 m3/h |
0.16...625 m3/h |
0.16...2'360m3/h |
0.16...625m3/h |
0.14...505 m3/h |
Process temperature
|
-200...+400°C |
-200...+400°C |
-200...+400°C |
-200...+400°C |
-50...+400°C |
Pressure range
|
PN10...160
Cl 150...600
JIS 10...40K
|
PN10...40
Cl 150...300
JIS 10...20K
|
PN16...40
CL 150...300
JIS10...20K
|
PN10...40
CL 150...300
JIS 10...20K
|
PN 64...250
Cl600...1500
|
Accuracy
|
+-0.75 % |
+-0.75 % |
+/-0.75% vol. fl. |
+/-0.75% vol. fl. |
+-0.75 % |
Display/Operation
|
Two line liquid crystal display
Push buttons
Quick Setup
|
Two line liquid crystal display
Push buttons
Quick Setup
|
Two line liquid Crystal display
Push nbuttons
Quick Setup
|
Two line liquid crystal display
Push buttons
Quick Setup
|
4 digit display
4 push buttons
|
Inputs
|
- |
- |
pressure input using Profibus PA or Foundation Fieldbus
|
pressure input using Profibus PA or Foundation Fieldbus
|
- |
Outputs
|
4...20mA
Pulse
Status
PFM
|
4...20mA
Pulse/Frequency
Status
PFM
|
4...20mA
Pulse
Frequency
Status
PFM
|
4...20mA
Pulse
Frequency
Status
PFM
|
4..20 mA
Pulse
Status
PFM
|
Communication
|
HART
Profibus PA
Foundation Fieldbus
|
HART
Profibus PA
Foundation Fieldbus
|
HART
Profibus PA
Foundation Fieldbus
|
HART
Profibus PA
Foundation Fieldbus
|
HART |
Ex-Approvals
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
Protection electronic
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP67
NEMA 4x
|
IP 67
NEMA 4x
|
IP65 |
Advantages
|
Proven capacitive sensor (installed base > 100,000) High resistance against: - Vibrations (over 1 g in all axes) - Temperature shocks ( > 150 K/s) - Dirty media - Water hammer
Galvanically isolated pulse output available (for alarm, limit value, etc.)
Permanent self-monitoring and diagnosis of electronics and sensor.
Correction of diameter mismatch.
No maintenance, no moving parts, no zero-point drift.
|
Proven capacitive sensor (installed base > 100,000) High resistance against: - Vibrations (over 1 g in all axes) - Temperature shocks ( > 150 K/s) - Dirty media - Water hammer
Galvanically isolated pulse output available (for alarm, limit value, etc.)
Permanent self-monitoring and diagnosis of electronics and sensor.
Correction of diameter mismatch.
Wafer version with standard 65 mm face-to-face length
No maintenance, no moving parts, no zero-point drift.
|
Measuring of Volume Flow and Temperature at the same time, calculation of Mass Flow using IAPWS-IF97/ASME for water or a linear equation for other liquids
Proven capacitive sensor (installed base > 100,000) High resistance against: - Vibrations (over 1 g in all axes) - Temperature shocks ( > 150 K/s) - Dirty media - Water hammer
Galvanically isolated pulse output available (for alarm, limit value, etc.)
Permanent self-monitoring and diagnosis of electronics and sensor.
Correction of diameter mismatch.
No maintenance, no moving parts, no zero-point drift.
|
Measuring of Volume Flow and Temperature at the same time, calculation of Mass Flow using IAPWS-IF97/ASME for water or a linear equation for other liquids
Proven capacitive sensor (installed base > 100,000) High resistance against: - Vibrations (over 1 g in all axes) - Temperature shocks ( > 150 K/s) - Dirty media - Water hammer
Galvanically isolated pulse output available (for alarm, limit value, etc.)
Permanent self-monitoring and diagnosis of electronics and sensor.
Correction of diameter mismatch.
Wafer version with standard 65 mm face-to-face length
No maintenance, no moving parts, no zero-point drift
|
Self-monitoring / self-diagnosis for measurement electronics and sensor
Proven and tested capacitive DSC-sensor: Not affected by temperature shocks or vibrations of the equipment
Current output is simultaneously available with pulse, alarm or limit output
Simulation of outputs signals
Each device is wet calibrated
|