Omnigrad T TSC310 | Omnigrad T TEC420 | Omnigrad S TAF16 | Omnigrad S TSC280 | Omnigrad S TSC281 | Omnigrad S TSC288 | Omnigrad S TSC262 | Omnigrad S TSC264 | Omnigrad S TSC266 | Omnigrad S TAF11 | Omnigrad S TAF12S | Omnigrad S TAF12D | Omnigrad S TAF12T | |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|
Measuring principle
|
Thermocouple for T < 1100 °C | Thermocouple for T < 1100 °C | Thermocouple for T < 1100 °C | Thermocouple for T < 1100 °C | Thermocouple for T < 1100 °C | Thermocouple for T < 1100 °C | Thermocouple for T < 1100 °C | Thermocouple for T < 1100 °C | Thermocouple for T < 1100 °C | Thermocouple for T > 1100 °C | Thermocouple for T > 1100 °C | Thermocouple for T > 1100 °C | Thermocouple for T > 1100 °C |
Characteristic / Application
|
Process industry, without head | Process industry, fast response | Furnaces, incinerators, cement industry | Bulk chemical and oil & gas industry | Bulk chemical and oil & gas industry | Bulk chemical and oil & gas industry | Bulk chemical and oil & gas industry | Bulk chemical and oil & gas industry | Bulk chemical and oil & gas industry | Ovens, furnaces | Platinum thermocouple, tile and glass industry | Platinum thermocouple, ceramic and glass industry | Platinum thermocouple, tile and glass industry |
Insert / Probe
|
M.I. cable not replaceable | M.I. cable replaceable | Replaceable | M.I. cable replaceable | M.I. cable replaceable | M.I. cable replaceable | M.I. cable replaceable | M.I. cable replaceable | M.I. cable replaceable | Replaceable | Replaceable | Replaceable | Replaceable |
Thermowell
|
To be ordered separately | To be ordered separately | To be ordered separately | To be ordered separately | To be ordered separately | Included, bar stock | |||||||
Wetted part material
|
1.4401, 2.4816 | 1.4401, 2.4816 | 1.4841, 1.4749, 1.4401, 2.4816 | Insert in 1.4401, 2.4816 | Insert in 1.4401, 2.4816 | Insert in 1.4401, 2.4816 | Insert in 1.4401, 2.4816 | Insert in 1.4401, 2.4816 | 1.4401, 1.4404, 2.4819, 2.4360, 2.4816 | KER 610 | KER 610, 710 | KER 610, 710 | KER 530, 710 |
Process connection
|
Adjustable: compression fitting with thread G or NPT | Adjustable: compression fitting available as separate accessory TA50, TA55 | Adjustable: 70 mm diameter flange in aluminium | Thread to thermowell: 1/2" NPT | Thread to thermowell: G1/2" | Thread to thermowell: G1/2", 1/2" and 3/4" NPT, M18x1.5, M14x1.5 | Thread to thermowell: 1/2" NPT (male or female) | Thread to thermowell: 1/2" NPT | Thread: 3/4" or 1" NPT Flange: 1", 1 1/2" or 2" ANSI 150, 300 or 600 RF |
Adjustable: 70 mm diameter flange in aluminium | Adjustable: 70 mm diameter flange in aluminium | Adjustable: 70 mm diameter flange in aluminium | Adjustable: 70 mm diameter flange in aluminium |
Diameter (mm)
|
1.5, 2, 3, 4.5, 6 | 6 | 14...27 | 3, 6 | 3, 6 | 3, 6 | 6 | 6 | 20, 24, 25 | 14, 17, 24 | 9 | 14, 15 | 24, 26 |
Reduced / Tapered tip
|
Not available | Not available | Not available | Not available | Not available | Not available | Not available | Not available | Standard | Not available | Not available | Not available | Not available |
Wetted part finishing (Ra)
|
1.6 µm | 1.6 µm | 1.6 µm | ||||||||||
Measuring / Operating range
|
K: -40...1100°C J: -40...750°C |
K: -40...1100°C J: -40...750°C |
K: -40...1100°C J: -40...750°C |
K: -40...1100°C J: -40...750°C |
K: -40...1100°C J: -40...750°C |
K: -40...1100°C J: -40...750°C |
K: -40...1100°C J: -40...750°C |
K: -40...1100°C J: -40...750°C |
K: -40...1100°C J: -40...750°C |
K: -40...1200°C J: -40...750°C |
R: 0...1600°C S: 0...1600°C B: 600...1700°C |
R: 0...1600°C S: 0...1600°C B: 600...1700°C |
R: 0...1600°C S: 0...1600°C B: 600...1700°C |
Max. process pressure at 20 °C
|
20 bar | 20 bar | 1 bar | Depends on thermowell | Depends on thermowell | Depends on thermowell | Depends on thermowell | Depends on thermowell | 480 bar | 1 bar | 1 bar | 1 bar | 1 bar |
Max. process pressure at 400 °C
|
Not defined | Not defined | Depends on thermowell | Depends on thermowell | Depends on thermowell | Depends on thermowell | Depends on thermowell | 300 bar | |||||
Accuracy
|
Class 2 | Class 2 | Class 2 | Class 1 or 2 | Class 1 or 2 | Class 1 or 2 | Class 1 or 2 | Class 1 or 2 | Class 1 or 2 | Class 2 | Class 2 | Class 2 | Class 2 |
Best response time
|
t50 = 0.8 s t90 = 2 s |
t50 = 2 s t90 = 5 s |
t50 = 0.8 s t90 = 2 s |
t50 = 0.8 s t90 = 2 s |
t50 = 0.8 s t90 = 2 s |
t50 = 2 s t90 = 5 s |
t50 = 2 s t90 = 5 s |
||||||
Head transmitter
|
PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | PCP 4...20 mA, HART, PROFIBUS-PA | |
Certificates / Approvals
|
Atex 2 G EEx-d | Atex 2 G EEx-d | Atex 1/2 GD EEx-d |