DETECTOR DG57 | |
![]() |
|
Measuring principle
|
Radiometric |
Characteristic / Application
|
Scintillation detector |
Supply / Communication
|
Transmitter |
Ambient temperature
|
-20°C...50°C 40°C...120°C with cooling jacket |
Process temperature
|
Any |
Process pressure absolute / max. overpressure limit
|
Any |
Wetted parts
|
Contactless |
Process connection
|
Contactless |
Hygienic
|
Contactless |
Sensor length
|
400mm...2000mm >2000mm cascade mode |
Max. measurement distance
|
Unlimited measuring range
|
Output
|
PCM |
Certificates / Approvals
|
ATEX TIIS |
Options
|
Kontilot for large measuring ranges |
Specialities
|
Interface measurement Calculation and sizing with Applicator CD-ROM |
Components
|
Source: Cs137, Co60 Source container: QG020, QG100, QG2000 Transmitter: FMG671 (P) |