|
Promass 83F |
Promass 80F |
Promass 83E |
Promass 80E |
Promass 83I |
Promass 80I |
Promass 83M |
Promass 80M |
Promass 40E |
Promass 83A |
Promass 80A |
Promass 83H |
Promass 80H |
Promass 64MP |
Promass 64F |
Promass 64M |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Measuring principle
|
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Coriolis |
Main features
|
The universal and multivariable flowmeter for liquids and gases |
The universal and multivariable flowmeter for liquids and gases |
An alternative to conventional volumetric flowmeters, this flowmeter has a low "cost of ownership". |
An alternative to conventional volumetric flowmeters, this flowmeter has a low "cost of ownership". |
Balanced single-tube system, "Fit-and-Forget" installation Design: Easy to clean, hygienic, careful handling of the medium - chemically resistant material |
Balanced single-tube system, "Fit-and-Forget" installation Design: Easy to clean, hygienic, careful handling of the medium - chemically resistant material |
The universal and multivariable flowmeter for liquids and gases |
The universal and multivariable flowmeter for liquids and gases |
The economical alternative to conventional volume flow meters |
The single-tube system for highest measuring accuracy with minimal flow rates. |
The single-tube system for highest measuring accuracy with minimal flow rates |
Balanced single-tube system, "Fit-and-Forget" installation Design: Easy to clean, hygienic, careful handling of the medium - chemically resistant material |
Balanced single-tube system, "Fit-and-Forget" installation Design: Easy to clean, hygienic, careful handling of the medium - chemically resistant material |
Mass and volume calculation for custody transfer |
Mass and volume calculation for custody transfer |
Mass and volume calculation for custody transfer |
Diameter
|
DN 8...150 5/16"...6" |
DN 8...150
5/16"...6"
|
DN 8...50
5/16"...2"
|
DN 8...50
5/16"...2"
|
DN 8...50
5/16"...2"
|
DN 8...50
5/16"...2"
|
DN 8...80 DN 8...25(MP)
5/16"...3" 5/16"...1"(MP)
|
DN 8...80 DN 8...25(MP)
5/16"...3" 5/16"...1"(MP)
|
DN 8...50
5/16"...2"
|
DN 1...4
1/24"...5/32"
|
DN 1...4
1/24"...5/32"
|
DN 8...50
5/16"...2"
|
DN 8...50
5/16"...2"
|
DN 8...25
5/16"...1"
|
DN 8...100
5/16"...4"
|
DN 8...80
5/16"...3"
|
Measuring range
|
0...800'000 kg/h |
0...800'000 kg/h |
0...70'000 kg/h |
0...70'000 kg/h |
0...70'000 kg/h |
0...70'000 kg/h |
0...180'000 kg/h 0...18'000 kg/h (MP) |
0...180'000 kg/h 0...18'000 kg/h (MP) |
0...70'000 kg |
0...450 kg |
0...450 kg |
0...70'000 kg/h |
0...70'000 kg/h |
0...900 kg/h |
0...350'000 kg/h |
0...180'000 kg/h |
Process temperature
|
-50...+200°C |
-50...+200°C |
-40...+125°C |
-40...+125°C |
-50...+150°C |
-50...+150°C |
-50...+150°C |
-50...+150°C |
-40...+125°C |
-50...+200°C |
-50...+200 |
-50...+200°C |
-50...+200°C |
-50...+150°C |
-50...+200°C |
-50...+150°C |
Pressure range
|
PN 16...100
Cl 150...600
JIS 10...63K
|
PN 16...100
Cl 150...600
JIS 10...63K
|
PN 40...100
Cl150...600
JIS 10...63K
|
PN 40...100
Cl150...600
JIS 10...63K
|
PN 16...100
Cl 150...600
JIS 10...63K
|
PN 16...100
Cl 150...600
JIS 10...63K
|
PN 16...100 PN350 (MP)
Cl 150...600
JIS 10...63K
|
PN 16...100 PN350 (MP)
Cl 150...600
JIS 10...63K
|
PN40...100
Cl 150...300
JIS 10...20K
|
PN 16...400
Cl 150...600
JIS 10...63K
|
PN 16...400
Cl 150...600
JIS 10...63K
|
PN 40
Cl 150...300
JIS 10...20K
|
PN 40
Cl 150...300
JIS 10...20K
|
PN 350 |
PN 16...100
Cl 150...600
JIS 10...63K
|
PN 16...100
Cl 150...600
JIS 10...63K
|
Accuracy
|
Mass flow:+-0.10%
Volume flow: +-0.15%
|
Mass flow: +-0.15%
Volume flow: +-0.20%
|
Mass flow:+-0.3%
Volume flow: +-0.45%
|
Mass flow: +-0.35 %
Volume flow: +-0.45 %
|
Mass flow:+-0.2 %
Volume flow: +-0.5 %
|
Mass flow: +-0.2 %
Volume flow: +-0.5 %
|
Mass flow:+-0.1%
Volume flow: +-0.25%
|
Mass flow: +-0.15%
Volume flow: +-0.25%
|
Mass flow: +-0.5 %
Volume flow: +-0.7 %
|
Mass flow:+-0.1 %
Volume flow: +-0.25 %
|
Mass flow: +-0.15%
Volume flow: +-0.25%
|
Mass flow:+-0.15%
Volume flow: +-0.5%
|
Mass flow: +-0.2 %
Volume flow: +-0.5 %
|
Mass flow: +-0.1 %
Volume flow: +-0.25 %
|
Mass flow: +-0.1 %
Volume flow: +-0.15 %
|
Mass flow: +-0.1 %
Volume flow: +-0.25 %
|
Display/Operation
|
Four line backlit
Touch control
|
Two line backlit
Push buttons
|
Four line backlit
Touch control
|
Two line backlit
Push buttons
|
Four line backlit
Touch control
|
Two line backlit
Push buttons
|
Four line backlit
Touch control
|
Two line backlit
Push buttons
|
Two line backlit
Operation via HART or FieldTool
|
Four line backlit
Touch control
|
Two line backlit
Push buttons
|
Four line backlit
Touch control
|
Two line backlit
Push buttons
|
Two line illuminated LCD/touch control |
Two line illuminated LCD
Touch control
|
Two line illuminated LCD
touch control
|
Inputs
|
Status
Current input
|
Status |
Status
Current input
|
Status |
Status
Current input
|
Status |
Status
Current input
|
Status |
Status |
Status
Current input
|
Status |
Status
Current input
|
Status |
Status |
Status |
Status |
Outputs
|
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
|
4...20mA
Pulse/Frequency
Status
|
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
|
4...20mA
Pulse/Frequency
Status
|
4...20mA
Pulse/Frequency (10KHz), active/passive
Relays/Status
|
4...20 mA
Pulse/Frequency
Status
|
4...20mA
Pulse/Frequency (10KHz), active/passive
Relays/Status
|
4...20mA
Pulse/Frequency
Status
|
4...20 mA
Frequency
Status
|
4...20mA
Pulse/Frequency (10KHz), active/passive
Relays/Status
|
4...20mA
Pulse/Frequency
|
4...20mA
Pulse/Frequency (10KHz), active/passive
Relays/Status
|
4...20 mA
Pulse/Frequency
Status
|
4...20mA
2xPulse (90°)Status
|
4...20mA
2xPulse (90°)Status
|
4...20mA
2xPulse (90°)Status
|
Communication
|
HART
Profibus PA
Profibus DP
Foundation Fieldbus
|
HART
Profibus PA
|
HART
Profibus PA
Profibus DP
Foundation Fieldbus
|
HART
Profibus PA
|
HART
Profibus PA
Profibus DP
Foundation Fieldbus
|
HART
Profibus PA
|
HART
Profibus PA
Profibus DP
Foundation Fieldbus
|
HART
Profibus PA
|
HART |
HART
Profibus PA
Profibus DP
Foudation Fieldbus
|
HART
Profibus PA
|
HART
Profibus PA
Profibus DP
Foundation Fieldbus
|
HART
Profibus PA
|
|
- |
|
Ex-Approvals
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
Protection electronic
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
Nema 4x
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
Nema 4x
|
IP 67
NEMA 4x
|
IP67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
IP 67
NEMA 4x
|
Features
|
S-DAT, T-DAT,F-Chip
Validation
Quick-Set-up
3 Totalizers
Pulsating flow
Advanced diagnostics
Batching
Concentration measurement
|
S-DAT
Validation
Quick-Setup
1 Totalizer
|
S-DAT, T-DAT, F-Chip
Validation
Quick-Set-up
3 Totalizers
Pulsating flow
Advanced diagnostics
Batching
Concentration measurement
|
S-DAT
Validation
Quick-Setup
1 Totalizer
|
S-DAT, T-DAT,F-Chip
Validation
Quick-Set-up
3 Totalizers
Pulsating flow
Advanced diagnostics
Batching
Concentration measurement
|
S-DAT
Validation
Quick-Setup
1 Totalizer
|
S-DAT, T-DAT,F-Chip
Validation
Quick-Set-up
3 Totalizer
Pulsating flow
Advanced diagnostics
Batching
Concentration measurement
|
S-DAT
Validation
Quick-Setup
1 Totalizer
|
Cost efficient
Alternative for mechanical meters
Integrated instrument data logger
|
S-DAT, T-DAT, F-Chip
Validation
Quick-Set-up
3 Totalizer
Pulsating flow
Advanced diagnostics
Batching
Concentration measurement
|
S-DAT
Validation
Quick-Setup
1 Totalizer
|
S-DAT, T-DAT, F-Chip
Validation
Quick-Set-up
3 Totalizers
Pulsating flow
Advanced diagnostics
Batching
Concentration measurement
|
S-DAT
Validation
Quick-Setup
1 Totalizer
|
prod_comp_text_20471 |
prod_comp_text_20463 |
prod_comp_text_20467 |
Advantages
|
Balanced dual-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid properties
Promass 83 with "Touch Control": operation from outside without opening the housing
Software packages may be updated for: - Dosage applications - Concentration measurement - Advanced diagnosis & 61623; "Quick Setup" menus for straightforward commissioning in the field
|
Balanced dual-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid properties
Software packages may be updated for: - Dosage applications - Concentration measurement - Advanced diagnosis
"Quick Setup" menus for straightforward commissioning in the field
|
High functionality. Simultaneous measurement of flow (mass, volume), density and temperature.
Balanced dual-tube system
Measurement is independent of fluid properties
Easy and cost-effective mounting
Low "cost of ownership"
Robust field housing of aluminium in IP 67 protection form
"Quick Setup" menus for straightforward commissioning in the field
|
High functionality. Simultaneous measurement of flow (mass, volume), density and temperature.
Balanced dual-tube system
Measurement is independent of fluid properties
Easy and cost-effective mounting
Low "cost of ownership"
Robust field housing of aluminium in IP 67 protection form
"Quick Setup" menus for straightforward commissioning in the field
|
Balanced single-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid properties
Promass 83 with "Touch Control": operation from outside without opening the housing
Software packages may be updated for: - Dosage applications - Concentration measurement - Advanced diagnosis
"Quick Setup" menus for straightforward commissioning in the field
|
Balanced dual-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid properties
Promass 83 with "Touch Control": operation from outside without opening the housing
Software packages may be updated for: - Dosage applications - Concentration measurement - Advanced diagnosis
"Quick Setup" menus for straightforward commissioning in the field
|
Balanced dual-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid properties
Software packages may be updated for: - Dosage applications - Concentration measurement - Advanced diagnosis
"Quick Setup" menus for straightforward commissioning in the field
|
Balanced dual-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid properties
Software packages may be updated for: - Dosage applications - Concentration measurement - Advanced diagnosis
"Quick Setup" menus for straightforward commissioning in the field
|
Low total costs
Measurement is independent of fluid
|
Balanced single-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid characteristics
Guaranteed product quality because the product is CIP-/SIP cleanable
Robust field housing of aluminium or stainless steel in IP 67 protection form
Wall-mount housing in IP 67 for the remote version
Promass 83 with "Touch Control": operation from outside without opening the housing
"Quick Setup" menus for straightforward commissioning in the field
|
Balanced single-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid characteristics
Guaranteed product quality because the product is CIP-/SIP cleanable
Robust field housing of aluminium or stainless steel in IP 67 protection form
Wall-mount housing in IP 67 for the remote version
Promass 83 with "Touch Control": operation from outside without opening the housing
"Quick Setup" menus for straightforward commissioning in the field
|
Balanced single-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid characteristics
Promass 83 with "Touch Control": operation from outside without opening the housing
Software packages may be updated for: - Dosage applications - Concentration measurement - Advanced diagnosis
"Quick Setup" menus for straightforward commissioning in the field.
|
Balanced single-tube system
High vibration immunity
Easy and cost-effective mounting
Measurement is independent of fluid properties
Promass 83 with "Touch Control": operation from outside without opening the housing
Software packages may be updated for: - Dosage applications - Concentration measurement - Advanced diagnosis
"Quick Setup" menus for straightforward commissioning in the field
|
prod_comp_text_20472 |
prod_comp_text_20464 |
prod_comp_text_20468 |