Promag 10W |
Promag 10P |
Promag 10H |
Magphant DTI200 |
Promag 50W |
Promag 50P |
Promag 50H |
Promag 53W |
Promag 53P |
Promag 53H |
Promag 23P |
Promag 23H |
Promag 51W |
Promag 51P |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
Measuring principle
|
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Electromagnetic |
Main features
|
Flow measurement of liquids in water or waste water applications |
Flow measurement of liquids in auxilliary circulations or waste water applications |
Flow rate measurement of liquids in simple hygienic or food applications |
Electromagnetic flowmeter for flow monitoring by means of limit value setting |
Standard applications for flow rate measurement of fluids in water / waste water applications |
Standard applictaions for flow rate measurement in chemical or process applications |
Standard applications for flow rate measurement of fluids in hygienic / food or process applications |
For high requirements in flow rate measurement of liquids in water / waste water applications |
For high requirements in flow rate measurement of liquids in chemical or process applications |
For high requirements in flow rate measurement of fluids in hygienic / food or process applications |
Flow rate measurement of liquids in chemical or process applications
Especially suitable for use in the chemical industry in two-wire technology
Suitable for use in Ex- zones
|
Flow rate measurement of liquids in hygienic / food or process applications
Especially suitable for use in the chemical industry in two-wire technology
Suitable for use in Ex-zones
|
PTB certified for custody transfer with cold water |
PTB certified for custody transfer with cold water |
Diameter
|
DN 25...600
1"...24"
|
DN 25...300
1"...12"
|
DN 2...100
1/12"...4"
|
DN15...DN2000
1/2"...80"
|
DN 25...2000
1"...78"
|
DN 15...600
1/2"...24"
|
DN 2...100
1/12"...4"
|
DN 25...2000
1"...78"
|
DN 15...600
1/2"...24"
|
DN 2...100
1/12"...4"
|
DN 25...200
25"...8"
|
DN 2...100
1/12"...4"
|
DN 25...2000
1"...78"
|
DN 15...600
1/2"...24"
|
Measuring range
|
0...9'600 m3/h |
0...2'400 m3/h |
0...282 m3/h |
0...56'550 m3/h |
0...110'000 m3/h |
0...9'600 m3/h |
0...282 m3/h |
0...110'000 m3/h |
0...9'600 m3/h |
0...282 m3/h |
0...1100 m3/h
|
0...282 m3/h |
0...110'000 m3/h |
0...9'600 m3/h |
Process temperature
|
-20...+80°C |
-40...+130°C |
-20...+150°C |
-20...+120°C |
-20...+80°C |
-40...+180°C |
-20...+150°C |
-20...+80°C |
-40...+180°C |
-20...+150°C |
-40...+180°C
|
-20...+150°C |
-20...+80°C |
-40...+150°C |
Pressure range
|
PN10...40
Cl 150
JIS 10...20K
AS 2129 Table E
|
PN10...40
Cl 150
JIS 10...20K
AS 2129 Table E
|
PN16...40 |
0...16 bar abs |
PN6...40
Cl 150...300
JIS 10...20K
AWWA Class D
AS 2129 Table E
|
PN10...40
Cl 150...300
JIS 10...20K
AS 2129 Table E
|
PN16...40 |
PN6...40
Cl 150...300
JIS 10...20K
AWWA Class D
AS 2129 Table E
|
PN10...40
Cl 150...3000
JIS 10...20K
AS 2129 Table E
|
PN16...40 |
PN10...40
Cl 150...300
JIS 10...30 K
|
PN16...40 |
PN6...40
|
PN10...40
|
Accuracy
|
±0.5% |
±0.5% |
±0.5% |
2% |
±0.5%
±0.2% (optional)
|
±0.5%
±0.2% (optional)
|
±0.5%
±0.2% (optional)
|
±0.2% |
±0.2% |
±0.2% |
±0.5% |
±0.5% |
±0.5%
±0.2% (optional)
|
±0.5%
±0.2% (optional)
|
Display/Operation
|
Two line display
Push buttons
|
Two line display
Push buttons
|
Two line display
Push buttons
|
Test function |
Two line display with backlit
Push button
|
Two line display with backlit
Push button
|
Two line display with backlit
Push button
|
Four line display with backlit
Touch control
|
Four line display with backlit
Touch control
|
Four line display with backlit
Touch control
|
Four line display
Touch control
|
Four line display
Touch control
|
Two line display with backlit
Push button
|
Two line display with backlit
Push button
|
Inputs
|
|
|
|
- |
Status |
Status |
Status |
Status
Current input
|
Status
Current input
|
Status
Current input
|
|
|
Status |
Status |
Outputs
|
4...20mA
Pulse
Status
|
4...20mA
Pulse
Status
|
4...20mA
Pulse
Status
|
4...20 mA
Relay
|
4...20 mA
Pulse/Frequency
Status
|
4...20 mA
Pulse/Frequency
Status
|
4...20 mA
Pulse/Frequency
Status
|
4...20 mA
Pulse/Frequency (active/passive)
Relays
Status
|
4...20 mA
Pulse / frequenz (aktive/passive)
Relays
Status
|
4...20 mA
Pulse / frequency(active/passive)
Relais
Status
|
4...20 mA , alternatively pulse, frequenzcy or status
|
4...20mA, alternatively pulse, frequency or status |
4...20 mA
Pulse/Frequency
Status
|
4...20 mA
Pulse/Frequency
Status
|
Communication
|
HART |
HART |
HART |
|
HART
Profibus PA
|
HART
Profibus PA
|
HART
Profibus PA
|
HART
Profibus PA
Profibus DP
Foundation Fieldbus
|
HART
Profibus PA
Profibus DP
Foundation Fieldbus
|
HART
Profibus PA
Profibus DP
Foundation Fieldbus
|
HART |
HART |
HART |
HART |
Ex-Approvals
|
FM
CSA
|
FM
CSA
|
FM
CSA
|
FM
CSA
|
ATEX
FM
CSA
|
ATEX
FM
CSA
TIIS
|
ATEX
FM
CSA
TIIS
|
ATEX
FM
CSA
|
ATEX
FM
CSA
TIIS
|
ATEX
FM
CSA
TIIS
|
ATEX
FM
CSA
|
ATEX
FM
CSA
|
ATEX
|
ATEX
|
Protection electronic
|
IP 67 (Nema 4x)
IP 68 (Nema 6P)
|
IP 67 (Nema 4x)
IP 68 (Nema 6P)
|
IP 67 (Nema 4x) |
IP 66
NEMA 4x
Type 4X
|
IP 67 (NEMA 4x)
IP 68 (Nema 6P)
|
IP 67 (NEMA 4x)
IP 68 (Nema 6P)
|
IP 67 (NEMA 4x) |
IP 67 (NEMA 4x)
IP 68 (Nema 6P)
|
IP 67 (NEMA 4x)
IP 68 (Nema 6P)
|
IP 67 (NEMA 4x) |
IP 67 (NEMA 4x) |
IP 67 (NEMA 4x)
|
IP 67 (NEMA 4x)
IP 68 (Nema 6P)
|
IP 67 (NEMA 4x)
IP 68 (Nema 6P)
|
Features
|
Monitoring of the medium
Bullet nose electrodes
|
Monitoring of the medium
Bullet nose electrodes
|
Monitoring of the medium
3A authorization and EHEDG-tested
|
A compact device for all applications |
S-DAT
Validation
Quick Set-Up
Monitoring of the medium
ECC
2 Totalizer
Bullet nose electrodes
|
S-DAT
Validation
Quick Set-Up
Monitoring of the medium
ECC
2 Totalizer
Bullet nose electrodes
|
S-DAT
Validation
Quick Set-Up
Monitoring of the medium
ECC
2 Totalizer
3A authorization and EHEDG-tested
|
S-DAT, T-DAT F-CHIP
Validation
Quick-Set-Up
ECC
3 totalizers
Bullet nose electrodes
Bi-directional totalizer
Pulsating flow
Density function
Mass calculation
Dosage
|
S-DAT, T-DAT, F- CHIP
Validation
Quick Set-Up
ECC
3 totalizers
Bullet nose electrodes
Bi-directional totalizer
Pulsating flow
Density function
Mass calculation
Dosage
|
S-DAT, T-DAT, F- CHIP
Validation
Quick Set-Up
ECC
3 totalizers
Bi-directional totalizer
Pulsating flow
Density function
Mass calculation
Dosage
3A authorization and EHEDG-tested
|
Two-wire MID
Intrinsically safe
For standard applications
S-DAT, T-DAT
Validation
2 Totalizers
Density function
Mass calculation
|
Two-wire MID
Intrinsically safe
For standard applications
S-DAT, T-DAT
Validation
2 Totalizers
Density function
Mass calculation
3A authorization and EHEDG-tested
|
S-DAT
Validation
Quick Set-Up
ECC
2 Totalizer
Bullet nose electrodes
PTB cold water approval
|
S-DAT
Validation
Quick Set-Up
ECC
2 Totalizer
Bullet nose electrodes
PTB cold water approval
|
Advantages
|
Ideal for simple measuring tasks
Current output displays current flow, pulse output as a status output
Service-friendly, functional design, simplified maintenance
Guaranteed safety of the application
Opeartion under extreme conditions (in shafts, vibrations or when permanetly under water) - the sensor van be installed separately from the transmitter and is available in the degree of protection IP 68.
|
Guaranteed saftey of the application
Service-friendly, functional design, simplified maintenance
Maximum resistance with aggressive media guaranteed with the PFTE lining
Operation under extreme conditions (in shafts, vibrations or when permanently under water) - the sensor can be installed separately from the measuring transmitter and is available in the degree of protection number IP 68.
|
Guaranteed saftey of the application
Servive-friendly, functional design, simplified maintenance
Guaranteed high bacteriological safety
Maximum resistance with aggressive media guaranteed with the PFA lining
Stainless steel sensor
Piggable sensor
|
Flow monitoring by means of limit value setting
Self-monitoring measuring system
Integrated test function to test the functionality of the electronics
|
Easy servicing and maintenance. Validation on site without removal of the sensor: - Optimized plant maintenance - Incorporation in QS-systems
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
"Quick Setup" menus for straightforward commissioning in the field
|
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
"Quick Setup" menus for straightforward commissioning in the field
|
Guaranteed product quality, because the product is CIP-/SIP cleanable and piggable
Stainless steel housing for high sanitary safety
Robust field housing in IP 67
IP 67 wall-mount housing for straightforward installation of the remote version
"Quick Setup" menus for straighforward commissioning in the field
|
Easy servicing and maintenance. Validation possible on site without removal of the transmitter: - Optimized plant maintenance - Incorporation in QS-systems
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
with "Touch Control": operation from outside without opening the housing.
"Quick Set-Up" menus for straightforward commissioning in the field
|
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
with "Touch Control": operation from outside without opening the housing
Software package may be updated for: - Dosage applications - Electrode cleaning - Increased operational safety
"Quick Setup" menus for straightforward commissioning in the field
|
Guaranteed product quality because the product is CIP-/SIP cleanable and piggable
Stainless steel housing for high sanitary safety
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
with "Touch Control": Operation from outside without opening the housing
Software packages may be updated: - for dosage applications - fur increased operational safety
"Quick Setup" menus for straightforward commissioning in the field
|
High measurement value stability, not affected by the flow rate
Reduced installation and operation costs
Robust field housing in IP 67 with seperate terminal compartment
"Touch Control": operation without opening the housing, also in Ex- environment
Connection to all mainstream transmitter power supplies and input cards of process systems
|
Guaranteed product quality because product is CIP-/SIP cleanable and piggable
Robust field housing IP 67
"Touch Control": operation without opening the housing, also in Ex- environment
Connection to all mainstream power supplies and input cards of process control systems
Reduced installation and operation costs
High measurement value stability, not affected by the flow rate
|
With national type examination for cold water(GER)
Fitting lengths to DVGW und ISO standards
Easy servicing and maintenance. Validation on site possible without the removal of the sensor: - Optimized plant maintenance - Incorporation in QS-systems
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straighforward installation of the remote version
"Quick Setup" menu for straightforward commissioning in the field
Operation under extreme conditions - The sensor can be installed separately from the transmitter and is available in the IP 68 protection form.
|
With national type examination for cold water (GER)
Fitting lengths to DVGW and ISO standards
Easy servicing and maintenance. Validation possible on site without removal of the sensor: - Optimized plant maintenance - Incorportation in QS-systems
Robust field housing in IP 67
Wall-mount housing in IP 67 for the straightforward installation of the remote version
"Quick Setup" menu for straightforward commissioning in the field
Operation under extreme conditions - The sensor may be installed separately from the transmitter and is available in the protection form IP68.
|