Таблицы»Сравнительная таблица предельных вибрационных уровнемеров для жидких сред

Сравнительная таблица предельных вибрационных уровнемеров для жидких сред

Liquiphant FTL20 Liquiphant T FTL20H Liquiphant T FTL260 Liquiphant FTL330H Liquiphant FTL330L Liquiphant M FTL50 Liquiphant M FTL50H Liquiphant M FTL51 Liquiphant M FTL51C Liquiphant M FTL51H Liquiphant S FTL70 Liquiphant S FTL71 Liquiphant S FDL60 Liquiphant S FDL61
Measuring principle
Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids Vibration Liquids
Characteristic / Application
most compact device
media independent
Focus factoryautomation
most compact
hygiene housing and process connections
CIP / SIP
Switch point 38mm
EHEDG approvals
  • compact device
  • media independent
  • Switch point 118mm
  • Compact device for hygiene applications
  • media independent
  • Completely welded with M12 plug
  • Surface finish up to 0,5um
  • Switch point 118mm
  • Sanitary process connections and housing
  • Compact device for hygiene applications
  • media independent
  • with cable outlet or elbow plug
  • Surface finish up to 0,5um
  • Switch point 118mm
  • Sanitary process connections and housing
  • Modular housing concept
  • wide range of process connections
  • Analogue and bus interfaces
  • Extensive certificate range (e.g. EEx,WHG)
  • compact, e.g. pipes
  • Modular & completely welded housing concept
  • Focus Food & Pharma
  • surface up to 0,3µ
  • wide range of process connections
  • Analogue and bus interfaces
  • Extensive certificate range (e.g. EHEDG,3A)
  • Compact, e.g. pipes
  • Modular housing concept
  • wide range of process connections
  • Analogue and bus interfaces
  • Extensive certificate range (e.g. EEx,WHG)
  • pipe extension up to 3m (6m option)
  • High protection against aggressive media by using antistatic coating
  • Modular housing concept
  • wide range of process connections
  • Analogue and bus interfaces
  • Extensive certificate range (e.g. EEx,WHG)
  • pipe extension up to 3m (6m option)
  • Temperature range up to 150°C (230°C option)
  • Modular & completely welded housing concept
  • Focus Food & Pharma
  • surface up to 0,3µ
  • wide range of process connections
  • Analogue and bus interfaces
  • Extensive certificate range (e.g. EHEDG,3A)
  • Compact, e.g. pipes
  • variable sensor length up to 3m (6m option)
  • Modular housing concept
  • High process temperatures up to 280°C
  • wide range of process connections
  • Analogue and bus interfaces
  • Extensive certificate range (e.g. EEx,WHG)
  • compact, e.g. pipes
  • Dual Sealing / Second line of defense
  • Modular housing concept
  • High process temperatures up to 280°C
  • wide range of process connections
  • Analogue and bus interfaces
  • Extensive certificate range (e.g. EEx,WHG)
  • compact, e.g. pipes
  • Dual Sealing / Second line of defense
  • Varable sensor length up to 3m (6m option)
  • SIL 3 acc. to IEC61508 / AK5 DIN V 19250
    Redundant accord. VdTUV in one device
    Permanent self function control
  • Anual test may be waived
  • SIL 3 acc. to IEC61508 / AK5 DIN V 19250
    Redundant accord. VdTUV in one device
    Permanent self function control
    Anual test may be waived
    Variable length up to 6000mm
    Supply / Communication
    19 ... 253V AC
    10 ... 35V DC-PNP
    ASI-Bus
    19 ... 253V AC
    10 ... 35V DC-PNP
    ASI-Bus
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 10 ... 55V DC-PNP
  • 19 ... 253 V AC
  • 10 ... 55 V DC-PNP
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA
  • 19 ... 253V AC, 2-wire
  • 10 ... 55V DC-PNP, 3-wire
  • DPDT, 19...253V AC, 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM, 2-wire
  • NAMUR with testbutton
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • PFM PFM
    Ambient temperature
    -40 °C ... 70 °C
    -25 °C ... 70 °C (ASi)
    -40 °C ... 70 °C
    -25 °C ... 70 °C (ASi)
    -40 °C ... 70 °C -40 °C ... 70 °C -40 °C ... 70 °C -50 °C ... 70 °C -50 °C ... 70 °C -50 °C ... 70 °C -50 °C ... 70 °C -50 °C ... 70 °C -50 °C ... 70 °C -50 °C ... 70 °C -25 °C ... 70 °C -25 °C ... 70 °C
    Process temperature
    -40°C ... 150°C -40°C ... 150°C -40°C ... 150°C -40°C ... 150°C -40°C ... 150°C -50°C ... 150°C -50°C ... 150°C -50°C ... 150°C -50°C ... 150°C
    (up to 230°C on request)
    -50°C ... 150°C -50°C (-60°C optional) ... 280°C
    (300°C 50h, cumulated)
    -50°C (-60°C optional) ... 280°C
    (300°C, 50h cumulated)
    -40°C ... 150°C -40°C ... 150°C
    Process pressure absolute / max. overpressure limit
    Vacuum ... 40 bar
    Vacuum ... 40 bar Vacuum ... 40 bar Vacuum ... 40 bar Vacuum ... 40 bar Vacuum ... 64 bar Vacuum ... 64 bar Vacuum ... 64 bar Vacuum ... 64 bar Vacuum ... 64 bar Vacuum ... 64 bar
    Vacuum ... 64 bar Vacuum ... 40 bar Vacuum ... 40 bar
    Min. density of medium
    0,7g/cm?
    (0,4g/cm? optional)
    0,7g/cm?
    (0,4g/cm? optional)
    0,7g/cm? 0,7g/cm? 0,7g/cm? 0,5g/cm? (0,4g/cm? optional) 0,5g/cm? (0,4g/cm? optional) 0,5g/cm? (0,4g/cm? option) 0,5g/cm? (0,4g/cm? optional) 0,5g/cm? (0,4g/cm? optional) 0,5g/cm?
    Wetted parts
    316L 316L 316Ti 316Ti 316Ti 316L, Alloy 316L 316L / Alloy ECTFE PFA (Edlon) PFA (Rubyred) PFA (conductive) Enamel 316L 316L / Alloy
    PFA and Enamel on request
    316L / Alloy
    PFA and Enamel on request
    316Ti, Alloy 316Ti, Alloy
    Process connection
    G1/2A, G3/4A, G1A, NPT1/2", NPT3/4", R1/2", R3/4" G1/2A, G3/4A, G1A, NPT1/2", NPT3/4", R1/2", R3/4" G1A, NPT1", R1" G1A, NPT1" G1A G3/4A, G1A, R3/4", R1, NPT3/4, NPT1, DIN DN25 ... DN100, ANSI 1" ... 4", JIS 25A ... 100A G3/4A, G1A, R3/4", R1, NPT3/4, NPT1, DIN DN25 ... DN100, ANSI 1" ... 4", JIS 25A ... 100A G3/4A, G1A, R3/4", R1, NPT3/4, NPT1, DIN DN25 ... DN100, ANSI 1" ... 4", JIS 25A ... 100A DIN DN25 ... DN100, ANSI 1" ... 3", JIS RF10 K 50 G3/4A, G1A, R3/4", R1, NPT3/4, NPT1, DIN DN25 ... DN100, ANSI 1" ... 4", JIS 25A ... 100A G3/4A, G1A, R3/4", R1, NPT3/4, NPT1, DIN DN25 ... DN100, ANSI 1" ... 4", JIS 25A ... 100A G3/4A, G1A, R3/4", R1, NPT3/4, NPT1, DIN DN25 ... DN100, ANSI 1" ... 4", JIS 25A ... 100A G1A, NPT1, DIN DN25 ... DN100, ANSI 1" ... 6", JIS RF 10 K 50 316Ti / Alloy G1A, NPT1, DIN DN25 ... DN100, ANSI 1" ... 6", JIS RF 10 K 50 316Ti / Alloy
    Hygienic
    Flush mount by use of weld in adapter Triclamp
    Dairy coupling
    Flush mount solutions
  • Flush mount
  • Triclamp
  • Dairy coupling
  • Triclamp, Dairy coupling, SMS, DRD Triclamp
  • Triclamp
  • Dairy coupling
  • Aseptic
  • DRD
  • SMS
  • Varivent
  • Triclamp FDA conform with PFA (Edlon)
  • Triclamp
  • Dairy coupling
  • Aseptic
  • DRD
  • SMS
  • Varivent
  • Dairy coupling
    Triclamp
    Sensor length
    64mm 64mm 130mm 130mm 130mm 65mm 65mm
  • Length 130mm (Liquiphant II)
  • 148mm ... 6000mm
  • ECTFE, PFA 130mm, 148mm ... 3000mm
  • Enamel 130mm, 148mm ... 1200mm
  • Length 130mm (Liquiphant II)
  • 148mm ... 6000mm
  • 65mm
  • Length 130mm (Liquiphant II)
  • 148mm ... 3000mm (6000mm optional)
  • 130mm 220mm ... 6000mm
    Output
    AC, DC-PNP, ASi AC, DC-PNP, ASi
  • AC, 2-wire
  • DC-PNP, 3-wire
  • DC-PNP
  • AC
  • DC-PNP
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • Profibus-PA,
  • 19 ... 253V AC
  • 10 ... 55V DC-PNP
  • 19...253V AC bzw 10...55V DC
  • 8/16mA, 11 ... 36V DC
  • NAMUR
  • PFM
  • PFM Nivotester FTL670
    PFM / Nivotester FTL670
    Certificates / Approvals
    CSA
    WHG
    GL
    Railway approval
    WHG
    EHEDG
  • WHG
  • CSA
  • WHG
  • CSA General Purpose
  • ATEX
    FM
    CSA
    TIIS
    EHEDG
    SIL2/3
    Marine
    ATEX
    FM
    CSA
    TIIS
    SIL2/3
    GL
    EHEDG
    FDA
    ATEX
    FM
    CSA
    TIIS
    SIL2/3
    ATEX
    FM
    CSA
    TIIS
    SIL2/3
    FDA
    ATEX
    FM
    CSA
    TIIS
    SIL2/3
    GL
    EHEDG
    FDA
    ATEX
    FM
    CSA
    TIIS
    SIL2/3
    ATEX
    FM
    CSA
    TIIS
    SIL2/3
    ATEX
    VdTUV100 (Liquid gases)
    WHG
    ATEX
    VdTUV 100
    WHG
    Options
    5m / 15ft cable
    Specialities
    Complete welded housing with M12 Plug IP66/68 IP65/67
  • Foamdetection
  • Detekt a densitychange
  • second line of defense
  • Foamdetection
  • Detect changes of the density
  • Foamdetection
  • Detect a densitychange
  • second line of defense
  • Foamdetection
  • Detekt a densitychange
  • second line of defense
  • Foamdetection
  • Detect changes of the density
  • Foamdetection
  • Detect a densitychange
  • second line of defense
  • Foam detection
  • Detect a densitychange
  • second line of defense
  • Permanent self monitored
    Redundant measuring system
    Selftest by pressing a button
    Permanent self monitored
    Redundant measuring system
    Selftest by pressing a button
    Components
  • FTL325P/FTL375P Interface PFM
  • FTL325N/FTL375N Interface NAMUR
  • FTL325P/FTL375P Interface PFM
  • FTL325N/FTL375N Interface NAMUR
  • FTL325P/FTL375P Interface PFM
  • FTL325N/FTL375N Interface NAMUR
  • FTL325P/FTL375P Interface PFM
  • FTL325N/FTL375N Interface NAMUR
  • FTL325P/FTL375P Interface PFM
  • FTL325N/FTL375N Interface NAMUR
  • FTL325P/FTL375P Interface PFM
  • FTL325N/FTL375N Interface NAMUR
  • FTL325P/FTL375P Interface PFM
  • FTL325N/FTL375N Interface NAMUR
  • FTL670, Fail-safe level switch interface FTL670, Fail-safe level switch interface

    "НПКП "Фотоника" - единственный официальный представитель Endress Hauser в Украине.